Repository navigation
Conversation
|
|
||
| None of the above clocks are guaranteed to be monotonic; NTP may correct time backwards, and GPS time may jump backwards | ||
| under foreseeable failure conditions. | ||
|
|
There was a problem hiding this comment.
Can we make use of PTP either across the board of instead of NTP. The accelerator whiterabbit syncs to GPS i believe, if everything could sync to PTP the they are all syncing to the same time source?
There was a problem hiding this comment.
Added a sentence about how this might happen in future.
I think pragmatically this is unlikely to happen in time for HRPD-X (we're already a bit squeezed on time) though.
May also need consideration for things like MNeuData in future (if that ends up happening...)
| ### Run starts / stops | ||
|
|
||
| Run starts and stops will be modified to contain **both** a local timestamp according to the streaming server, and a | ||
| GPS timestamp according to the streaming control board. This will require changes to the SCB firmware and |
There was a problem hiding this comment.
it will also require changes to the schemas, which currently only have one start time / stop time field.
There was a problem hiding this comment.
Yep ISISComputingGroup/streaming-data-types#19 if this ADR is accepted.
…tes using perf counter periodically synced to system time.
Kind of part of ISISComputingGroup/DataStreaming#119, but also a bit more general...